generator set for stationary use Iveco FPT Cursor 10 model with Marelli . This machine, reconditioned in 2023 and used in 2009 for a total of 134 hours of work, represents an effective and powerful solution for continuous energy needs.

Visual Description and Construction

The stationary generator set presents itself as a solid and well-designed unit, built to withstand harsh operating conditions. Its sturdy structure is made of painted steel, which offers resistance to atmospheric agents and guarantees long life. The soundproof case reduces the noise produced during operation, making the generator suitable for installations in residential and commercial environments.

The dimensions of the machine, which are not specified in detail, are generally compact for a generator of this power, making it easy to position in limited spaces.

Main Components

The generator set is equipped with several fundamental components:

  1. Iveco FPT Cursor 10 Engine : This high quality diesel engine is designed to offer high performance with optimal efficiency. With a power output of 300 kVA (240 kW actual prime power), the Cursor 10 motor is known for its reliability and durability.

  2. Marelli alternator Mark 2 voltage regulator , which ensures a stable and continuous energy supply. This configuration is ideal for variable loads, guaranteeing an excellent response to variations in demand.

  3. On-board diesel tank : The tank has a capacity of 800 liters and includes a collection tank for liquids, ensuring safe management of fuels. Furthermore, the system is set up with quick-fit diesel connections for easy connection to external auxiliary tanks.

Mechanical Characteristics

  • PRP power : 300 kVA (240 kW effective)
  • Engine : Iveco FPT Cursor 10
  • Alternator : Marelli with Mark 2 regulator
  • Diesel tank capacity : 800 litres
  • Working hours : 134 hours

These characteristics make the generator set suitable for industrial and commercial applications, where continuous reliability and considerable power are required.

Usage Procedure

To use the generator set for stationary use , follow these simple steps:

  1. Preliminary check : Before starting the generator, make sure that the diesel tank is full and that the engine oil level is adequate. Also check for leaks in the system.

  2. Starting : Use the control panel to start the engine. An automatic starting system may be present, facilitating the process.

  3. Monitoring : During operation, keep an eye on the control panel to monitor operating parameters, such as voltage, current and operating hours.

Matching accessories

The generator set can be customized with various accessories, including:

  • Auxiliary external tanks : to increase the autonomy of the generator.
  • Remote monitoring systems : to manage performance and energy consumption in real time.
  • Connection cables : to ensure safe and stable connections with other equipment.

Calculation of Optimal Use Parameters

To optimize the use of the generator , it is useful to apply some mathematical formulas:

  1. Generator autonomy : If the hourly consumption is, for example, 20 litres, the autonomy is calculated as follows:

    Autonomy (hours)=Tank capacity (litres)Consumption (litres/hour)\text{Autonomy (hours)} = \frac{\text{Tank capacity (litres)}}{\text{Consumption (litres/hour)}}

    With an 800 liter tank:

    Autonomy=80020=40 hours\text{Autonomy} = \frac{800}{20} = 40 \text{ hours}
  2. Calculation of Electrical Power : Make sure that the connected load does not exceed 300 kVA to avoid overloads, monitoring the absorbed power.

Workable Materials

The generator set is designed to power various applications, for example:

  • Industrial sector : to power machinery and production plants.
  • Outdoor events : to guarantee energy at fairs, concerts or events.
  • Emergencies : as an auxiliary energy source during blackouts.

Maintenance and Safety

Maintenance of the generator set is essential to guarantee its correct functioning. It is advisable to carry out regular checks which include:

  • Oil Change : Follow the manufacturer's guidelines for replacement frequency.
  • Checking the filters : Keep the air and fuel filters clean.
  • Battery inspection : Make sure it is charged and in good condition.

In terms of safety, ensure that the generator is used in accordance with current regulations. If the generator does not have CE certification, it is important to adapt it to ensure that it meets the required safety standards.

Rating of Good Used

To understand if a generator set represents a good purchase, consider the following aspects:

  • Operating hours : a generator with few operating hours is preferable, as it is less subject to wear.
  • Physical Condition : Check for signs of wear or damage.
  • Documentation : Check for regular maintenance records.

Sectors of Use and Advantages of Purchasing Used

The stationary generator set is suitable for a variety of sectors, from industrial to residential. Buying a used generator offers several advantages, such as a reduced price and the possibility of obtaining a high-quality product at a lower cost. Choosing a reconditioned generator in 2023, after only 134 hours of use, represents an advantageous option for those looking for high performance at a low cost.

In conclusion, the stationary generator set with Iveco FPT Cursor 10 Marelli alternator is an ideal choice for those who need a reliable and powerful energy source. With the right maintenance and monitoring practices, this machine can provide excellent performance for many years

Specific details

Continent Europe
Nation Italy
Marche region
Province of Ancona

Advertisement details

Ad ID 96485

Newsletter

Always stay updated

Used Machinery Ads

Explore the vast selection of quality machinery on AnnunciMacchinariUsati.com. From industrial equipment to special vehicles, find the best offers in the world of used machinery. Reliability, transparency and wide variety: all just a click away. Find out more today!

Categories